STV200/400K Surge Protective Devices
C US
|
SolaHD STV 200/400K Series offers continuous protection from damaging voltage transients and electrical noise
commonly found at the service entrance or distribution panel. The modular design of the STV 200/400K allows
for installation flexibility and its’ robust design allows for installation in the most severe exposure locations. They are capable of handling the high-impulse, potentially damaging transients commonly found at the service entrance or
distribution panels. The modular design of the STV 200/400K allows for installation flexibility. Its robust design allows for placement in the most severe exposure locations.
The STV 200/400K utilizes patented circuitry to monitor
the status of all protection modes, including neutral to ground. Should protection be unavailable in any mode, the Green LED will be extinguished, and the Red LED will be illuminated. In addition, high isolation form C dry contacts provide remote monitoring of suppression system failure, under voltage, phase and power loss. The STV 200/400K patented suppression integrity monitoring indicates failure
for both shorted or opened suppression components.
These devices are designed to meet UL 1449 (second
edition), UL 1283 and cUL Listed. These units are ANSI/IEEE C62.11, C62.41, C62.45 Categories A, B, and C3 tested. They are built to meet your unique requirements, and are available in hardwire, three phase configuration. They are designed for years of trouble free operation and require little or no operator intervention after installation.
On this page: Related Products, Features, Dimensions & Wiring Specifications, Specifications, Selection Table |
Applications
The STV 200/400K Series can be a facility-wide product family and may be installed from service entrances to distribution panels to branch panels.
- Industrial Plants
- Commercial Buildings
- Institutional Facilities
- Any facility that has an environment with
electronics based equipment
|
Printable
versions of the following sections are available by selecting one
of the pdf files to the left.
- Modular design allows for flexibility
- Surge current capacity of 200 to 400 kA per phase
- Industry’s highest surge current repeatability
- All modes transient protection (L-N, L-G, and N-G)
- Form C contact and audible alarm status indications
- Internal/external monitoring, including neutral to ground
- UL rated 200 kAIC with component level fusing
for safe operation
- EMI/RFI Filtering
- UL 1449 (second edition), UL 1283, and cUL Listed
- ANSI/IEEE C62.11, C62.41, C62.45
Categories A, B, and C3 tested
- Tested to NEMA LS1, ISO 9001
- NEMA 12 enclosure, available options
NEMA 3R, 4, and 4X
- Optional rotary disconnect, transient counter,
and remote monitor panel
- 5 Year Limited Warranty
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
STV 200K |
16 |
14 |
8 |
16.75 |
12 |
.31 |
41 (18.60) |
40 A |
#8 |
15 A–100 A |
#14–#2 |
STV 400K |
20 |
16 |
9 |
21.25 |
10 |
.44 |
56 (25.40) |
100 A |
#2 |
15 A–100 A |
#14–#2 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
STV 200K |
16 |
14 |
8 |
16.75 |
12 |
.31 |
41 (18.60) |
40 A |
#8 |
15 A–175 A |
#14–2/0 |
STV 400K |
20 |
16 |
9 |
21.25 |
10 |
.44 |
56 (25.40) |
100 A |
#2 |
15 A–175 A |
#14–2/0 |
|
|
|
|
|
|
|
|
|
Input Vac |
120Y/208 V |
277Y/480 V |
480 V |
120Y/208 V |
277Y/480 V |
480 V |
Three Phase Wye, 4 W + G |
Three Phase Wye, 4 W + G |
Three Phase ∆, 3 W + G |
Three Phase Wye, 4 W + G |
Three Phase Wye, 4 W + G |
Three Phase ∆, 3 W + G |
Maximum Continous
Operating Voltage (MCOV) |
120 V = 125%, All others voltages 115% |
Line Frequency |
47–63 Hz |
Connection/
Mounting Type |
Internally connected/Wall Mounted (Mounting hardware 1/4 in.) |
Enclosure |
NEMA 12 (NEMA 3R, 4, 4x optional) |
Modes of Protection |
All Modes: L-N, L-L, L-G, N-G |
Saftey Agency Approvals |
UL 1449, UL 1283, cUL |
| |
|
L-N |
400 V |
700 V |
N/A |
400 V |
700 V |
N/A |
L-L |
700 V |
1,500 V |
1,500 V |
700 V |
1,500 V |
1,500 V |
L-G |
400 V |
700 V |
1,500 V |
400 V |
700 V |
1,500 V |
N-G |
400 V |
700 V |
N/A |
400 V |
700 V |
N/A |
AIG Rating |
200 kAIC |
Status Indication |
LED’s status indicator, Audible alarm, and Form ‘C’ contact only relay |
Response Time |
< 0.5 nsec. |
Operating Temperature |
-40°C to +50°C |
Operating Humidity |
0% to 95% Non-condensing |
Noise Attenuation |
50 dB Maximum |
| |
|
Per Phase |
200 kA |
400 kA |
200 kA |
400 kA |
200 kA |
400 kA |
Line to Neutral |
100 kA |
200 kA |
100 kA |
200 kA |
100 kA |
200 kA |
Line to Line |
100 kA |
200 kA |
100 kA |
200 kA |
100 kA |
200 kA |
Line to Ground |
100 kA |
200 kA |
100 kA |
200 kA |
100 kA |
200 kA |
Neutral to Ground |
100 kA |
200 kA |
100 kA |
200 kA |
100 kA |
200 kA |
Warranty |
5 year limited warranty |
|
|
|
STV 400K-10Y |
120/208 V |
Three Phase Wye 4 wire + Ground |
STV 200K-10Y |
120/208 V |
Three Phase Wye 4 wire + Ground |
STV 400K-27Y |
277/480 V |
Three Phase Wye 4 wire + Ground |
STV 200K-27Y |
277/480 V |
Three Phase Wye 4 wire + Ground |
STV 400K-48D |
480 V |
Three Phase ∆ 3 wire + Ground |
STV 200K-48D |
480 V |
Three Phase ∆ 3 wire + Ground |
What's New |
Products |
Cross Reference |
Technical Support |
Contact Us |
Search |
Surge Protection Home
© 2000
Sola/Hevi-Duty. All Rights Reserved.
Sola/Hevi-Duty Hardwired Surge Protection
|
 |