Sola/Hevi-Duty
Home Search
What's New
Products
Cross Reference
Technical Support
Contact Us
Password Protected Area for Reps and Distributors
Product Specials

PDF Links
Catalog Page
Manual


PDF files require Acrobat Reader
to view them.
Click above to download it
for free.

Products
Home > Products > Surge & Noise Protection > Data/Signal Line > STC-DRS


STC-PoESTC-DRS Series DIN Rail Protection

The Sola STC-DRS Series is a DIN Rail mountable, single pair surge protection module implementing three-stage hybrid technology.
This module addresses over-voltage transients with gas tubes and silicon avalanche components. In addition, sneak currents are mitigated with resetable fuses (PTCs). The PTC increases resistance by several orders of magnitude when over currents exceed safe levels. A normal state resumes when over currents are removed. The ability to self-restore in this manner significantly increases suppressor performance and survivability.

The STC-DRS Series mounts onto a standard 35mm industrial DIN rail. There are three Field Side and three Electronics Side screw terminals. One is reserved for a shield. Three electrically tied ground terminals are provided for grounding the unit to building-approved ground. The shield is isolated from ground.

On this page: Features, Selection Table, Dimensions


Features Top

  • Low-Voltage Data Surge Protection
  • Three-Stage Hybrid Protection
  • Sneak/Fault Current Protection With Restable Fuses(PTCs)
  • Low Profile Packaging
  • Easy Installation
  • Fits Standard 35mm DIN Rail
  • Fast Response Time <1 Nanosecond
  • UL 497B Listed
  • 5 Year Warranty

 


Selection Table Top

Model Number

Max Peak Signal Voltage

Nominal Breakdown Voltage

Max Current 1p 10X100µs (Occuraences)

Peak Current 8X20µs

Typ Cap (PF)

Max Continuous Current

Nominal Series Resistance

 STC-DRS-232
15
22
>100
10KA
1500
150ma
5
 STC-DRS-036
30
36
>100
10KA
1500
150ma
5
 STC-DRS-060
52
60
>100
10KA
1500
150ma
5

Dimensions Top
Note:These protectors are intended for indoor use on communication loop circuits that have been isolated from the Public Switch Telephone Network.

The communication loop circuits shall not be exposed to accidental contact with the electric light or power conductors. The protectors shall be installed per the applicable requirements of the National Electric Code, ANSI/NFPA 70.

What's New | Products | Cross Reference | Technical Support | Contact Us | Search | Surge Suppression - Home

© 2007 Sola/Hevi-Duty. All Rights Reserved.

Sola/Hevi-Duty Data/Signal Line Surge Protection