Silver LineSilver Line Series - Single & Multi-Output Linears

The Silver Line series follows the industry accepted footprint for open frame, linear power supplies. Sola improves on this design by offering standard screw terminal connections and optional covers for safety considerations.

On this page: Features, Applications, Specifications, Selection, Dimensions, Manuals

Features Top
  • Easy-to-install screw terminal connections
  • Cover options
  • Industry standard footprint
  • Universal input and approvals (115/230 VAC)
  • Low noise, extremely quiet DC output for noise sensitive or analog circuitry
  • Fast transient response. Ideal for test applications.
  • Built-in OVP on 5 V models and optional on 12, 15 and 24 V models
  • Automatic resetting overload protection
  • Short circuit protected
  • Two year warranty
Applications Top
  • Industrial control circuits and components
  • Instrumentation
  • Drives
  • CNC machinery
  • Equipment for food industry
  • Microprocessor circuits
  • Analog circuits
  • Noise sensitive circuitry and sensors
Specifications Top

 

Parameter Condition Limit

Input

 Input Voltage  x  100/120/220/230/240 
 VAC Selectable
 Input Frequency  x  47-63 Hz

  Output

 Line Regulation   for 10% change  0.05%
 Load Regulation   for 50% change  0.05%
 Ripple  x  3.0 mV maximum 
 Peak-to-Peak
 DC Output 
 Adjustment Range
 x  ±5% Minimum
 Overvoltage Protection  x
 All 5-Volt outputs include
 build-in OVP as standard
 (setting is 6.2 V ±0.4 V) 
 OVP is optionally available
 on other types
 Transient Response Time  at 50% Load Changes  50 msec.
 Overload Protection    Automatic current 
limit foldback
 Remote Sensing
 Available to compensate 
 for output voltage drop 
 on selected models

 0.5 VDC

 General

 Operating Temperature
 Range

 Derate to 40% at +70°C

 0 to +50°C
 Storage Temperature Range
  -25°C to +85°C
 Temperature 
 Coefficient (Typical)
   0.01%°C
 Stability After warm-up  ± 0.5%
 Vibration Method 514  Per MIL-STD-810C
 Shock Method 516  Per MIL-STD-810C
 EMI/RFI
 Linear power supplies have
 inherently low conducted
 and radiate noise levels
 For most system applications
 they will meet requirements
 of FCC Class B and VDE 0871
 for Class B
 Cover Option

Derate power by an additional 15%

 Cooling

Forced air. 
20 CFM required for full rating 
Derate 30% without cooling.

 *Specifications are typical. Load Regulation on outputs without Remote Sense, 0.1% typical.


Selection Top

 

Catalog
Number
OUTPUT 1 OUTPUT 2 OUTPUT 3 Case
 SLS-05-030-1T  5 V @ 3 A*# - -

 A

 SLS-05-060-1T  5 V @ 6 A*# - -  B
 SLS-05-090-1T  5 V @ 9 A*# - -  C
 SLS-05-120-1T  5 V @ 12 A*# - -  I2
 SLS12-017T1  12 V @ 1.7 A#
or 15 V @ 1.5 
- -  A
 SLS-12-034T  12 V @ 3.4 A# - -  B
 SLS-12-051T  12 V @ 5.1 A# - -  C
 SLS-12-068T  12 V @ 6.8 A# - -  I2
 SLS-15-045T  15 V @ 4.5 A# - -  C
 SLS-15-060T  15 V @ 6 A# - -  I2
 SLS-24-012T  24 V @ 1.2 A# - - A
 SLS-24-024T  24 V @ 2.4 A# - - B
 SLS-24-036T 24 V @ 3.6 A# - -  C
 SLS-24-048T 24 V @ 4.8 A#  - -  I2
 SLS-24-072T 24 V @ 7.2 A#  - -  K
 SLS-24-120T  24 V @ 12.0 A#  - -  L
 SLD12-1010-12T1 12 V @ 1 A
or 15 V @ .8 A
-12 V @ 1 A 
or -15 V @ .8
- H1
 SLD12-1818-12T1 12 V @ 1.8 A
or 15 V @ 1.5 A
-12 V @ 1.8 A
or -15 V @ 1.5 A
- D
 SLD-12-3434-12T 12 V @ 3.4 A# -12 V @ 3.4 A# - I3
 SLD-15-3030-15T 15 V @ 3 A# -15 V @ 3 A# - I3
 SLD-12-6034-05T  5 V @ 6 A*#  12 V @ 3.4 A# - I1
 SLD-12-3015-05T 5 V @ 3 A*#  12 V@ 1.5 A - C1
 SLT12-20404-12T1 5 V @ 2 A*# 12 V @ .4 A
or 15 V @ .4 A
-12 V @ .4 A
or -15 V @ .4 A
H2
 SLT12-31010-12T1 5 V @ 3 A*# 12 V @ 1 A#
or 15 V @ .8 A
-12 V @ 1 A#
or -15 V @ .8 A
F
 SLT12-61010-12T1 5V @ 6 A*# 12 V @ 1 A
or 15 V @ 1 A
-12 V @ 1 A
or -15 V @ 1 A
I4
 SLT12-61818-12T1  5V @ 6A*# 12 V @1.8 A
or 15 V @1.5 A
-12 V @ 1.8 A 
or -15 V @ 1.5 A
G2
 SLT24-30530-05T1 5V @ 3A* -5 V @ .5 A* 24 V @ 3 A* G1
 Over Voltage Protector (OVP)
 SLO-12-000-1

6.2 V to 34 V
Adjustable @ 8 V

For Cases B through K J1
 SLO-12-000-TB

6.2 V to 34 V
Adjustable @ 8 V

For Case A or Cases B through K 
(when used with a cover)
J2

Note:
 
*  With Built-in OVP
#  With Remote Sense (R.S.)
1. 12/15 Volt models are factory set for 12 Volt operation. 
    15 Volt operation is field adjustable. 