Sola/Hevi-Duty
Home Search
What's New
Products
Cross Reference
Technical Support
Contact Us
Product Specials
Password Protected Area for Reps/Distributors

arrow2.gif (353 bytes) MultiLink FAQ
arrow2.gif (353 bytes) To check for the latest UPS versions
User Manual


PDF files require Acrobat Reader
to view them.
Click above to download it
for free.

 

Products
Home > Products > Uninterruptible Power Systems >Software

 

MultiLink Network Shutdown Software (Version 3.0)

Install this software.
Software Requirements
 

On this page: Compatible Operating Systems, Features, MultiLink Configurations, Cable Connections, SNMP Connection, Monitoring with Multiple Types Connections, Cables for Serial Port Connection, MultiLink Part Numbers

 

Compatible Operating Systems Top

 

Operating System Current MultiLink Release
 Microsoft Windows NT/2000/95/98/ME 
 for Intel
Build 9 OEM, October 31, 2001
 Novell NetWare 4.11+, 5.0+ Build 9 OEM, October 31, 2001
 SunSoft Solaris for SPARC, 2.6, 7, 8 Build 9 OEM, October 31, 2001
 Hewlett Packard HP-UX for HP 9000, 11.0 Build 9 OEM, October 31, 2001
 IBM AIX for RISC System/6000, 4.3, 5L Build 9 OEM, October 31, 2001
 Linux for Intel, 2.2-2.4 Kernel Build 9 OEM, October 31, 2001

Features Top

  • Detailed instrumentation
  • Simple Navigational Tree
  • Customizable Event Management
  • Protects data on one or more computers
  • Monitor every aspect of your power
  • React to power problems with customizable event management
  • Manage over the network with optional Network Administration License
  • Prevents the loss of valuable data by performing unattended, orderly shutdown on one computer or multiple networked computers with optional MultiLink License Kit
  • Configurable responses to UPS status changes
  • Notification via alphanumeric pagers, e-mail and on-screen messages
  • Support for standards such as SNMP (Simple Network Management Protocol)
  • Developed with Java™ technology
  • Supports both serial interface and contact closure interface
  • Ready-made or user-made cables
  • Manage and monitor UPSs over the network with optional Network Administration License
MultiLink Configurations Top

MultiLink is configured according to the method a computer uses to monitor the status of a UPS, either through an SNMP card or by a direct cable connection to the serial port. The software is designed to monitor any part of a network. Its functionality permits it to monitor any Sola/Hevi-Duty UPS that can be contacted via serial cable, contact closure, an Ethernet or the Internet, but the software’s functionality does not require networked computers and UPSs. 

Configure MultiLink according to the type of connection between the computer and UPS. The various methods are shown in Figures 1, 2, and 3.

Cable Connections Top

Figure 1 below shows the simplest possible MultiLink installation. MultiLink can be configured to monitor the UPS and, if utility power fails or another problem arises, MultiLink can notify Computer #1 and personnel about the problem. In the event of a serious power problem, MultiLink can be configured to prompt the shutdown of Computer #1’s operating system.


Figure 1: Direct cable connection

Figure 2 shows the same type of serial connection to a computer on a network (Computer 1). With either serial communications or a contact closure connection, MultiLink can send notifications to all computers (Computers #2-5) on a network (These computers must be running MultiLink). With a MultiLink Network Shutdown License on Computer #1, MultiLink can send notifications to those computers when needed.

 


Figure 2: UPS connected by cable to one computer on network

SNMP Connection Top

Figure 3 shows one example of a UPS with an SNMP connection. Any computer running MultiLink can monitor the status of the UPS and send notifications to the other computers. Some SNMP cards impose a limit on the number of computers that can receive notifications.


Figure 3: UPS with SNMP card on network

Monitoring with Multiple Types of Connections Top

A computer can be set up to monitor and control more than one UPS, including UPS models requiring different types of connections. For example, with network connections and the appropriate upgrade licenses, any computer in Figures 1, 2 and 3 could monitor the status of any UPS on the network and send notifications to other computers, allowing them to shut down if needed.

A computer can receive alerts from only one UPS, but can monitor the status of any UPS on a network.

Figure 4 shows possible interconnections of host computers, targeted clients and UPS models with varying connections. In this figure, any computer can be configured to monitor any UPS or MultiLink installation.


Figure 4: Multiple Users (SNMP and Serial Port Connections)

Cables for Serial Port Connection Top

Part No Description Function UPS Support
 SML39P9S  MultiLink Serial Interface
 cable for use with
 MultiLink 3.0
 Connects UPS to
 computer running
 MultiLink 3.0. Provides
 detailed instrumentation 
 & parametric data.
 Series 3000, 4000, S4K
 and S5K Modular
 SML9P9S  MultiLink Contact Closure
 Interface cable
 Connects UPS to
 computer running
 MultiLink 1.x or 3.0. 
 Provides On-Battery,
 Low-Battery signals only.
 UPS models equipped
 with DB9 ports (including
 Series 2000, 3000, 4000,
 S4K and S5K Modular

If you prefer to build your own cable, click here

MultiLink Part Numbers Top

MultiLink License Kits enable in-band shutdown on more than one computer, or the management of multiple UPSs and software installations. License kits may be purchased from your Sola/Hevi-Duty sales representative.

Part No Description
 SML3ACD  MultiLink Software on CD
 MLLKB  MultiLink License Kit, 5 Computers
 MLLKC  MultiLink License Kit, 10 Computers
 MLLKD  MultiLink License Kit, 20 Computers
 MLLKG  MultiLink License Kit, 100 Computers
 MLLKU  MultiLink License Kit, Unrestricted
 MLLNA  MultiLink Network Administration License


What's New | Products | Cross Reference |
Technical Support | Contact Us | Search | Home